Advanced power measurement, control and management for your remote IT equipment.
The Avocent Power Management Distribution Units (PM PDUs) include single-phase and three-phase models that support strip-level metering, outlet-level metering or outlet-level metering and switching. This advanced family of rack PDUs includes horizontal and vertical models for a variety of rack configurations in branch and remote offices. With the ability to support up to 22 kW and models that include support for C19 outlets, the Avocent PM PDUs are well positioned to support the high rack density found in organizations today.
The PM PDUs include an LED display and a built-in browser interface for local and remote access to real-time data. The metering features, along with the capability to set custom thresholds, allow companies to optimize their electrical infrastructure, without the risk of downtime due to overloaded circuits.
The PM 1000 PDUs enable companies of all sizes to accurately measure the current, voltage and power for the entire strip and the circuits within. The PM 2000 and PM 3000 PDUs take this a step further to support outlet-level metering and switching capability (PM 3000 PDUs only) to provide data center professionals the tools they need to monitor, measure, reduce and manage the growing power consumption costs of IT equipment.
All of these PDUs include advanced features that consist of a built-in network port for access to the browser interface, daisy chain ports for easy installation and expansion and support for external, environmental sensors.
For a total solution, the PM 1000/2000/3000 devices can be used with other Avocent appliances for integrated IP access to the attached equipment, along with power measurement and/or control for improved remote management.
When used with the DSView® 3 management software, users gain secure access and control across multiple locations. The optional DSView 3 Power Manager plug-in allows real-time and historical reporting of capacity, consumption and cost across single PDUs or groups of PDUs.
Features and Benefits
- Outlet-Level, Phase-Level and Strip-Level Current/Voltage/Power Metering with Threshold/Alert Capabilities – Provides preemptive notification of any impending overload issues before they occur and simplifies the task of installing new equipment (Note- measurement resolution +/- %5)
- Capability to Remotely Switch Outlets Through On-Board Web Interface, DSView 3 Management Software – Allows power to hung up IT equipment to be recycled, turned on or turned off remotely for faster resolution time (not available on PM 1000 or PM 2000 PDUs)
- On-Board Web Interface – Can be installed for direct access right out of the box or it can be configured as part of a larger integrated solution using the DSView 3 management software
- IP and Serial Interface Options – Options to install by connecting directly to the network or save IP connections by using the serial interface to connect directly to Avocent appliances already connected to the network
- Daisy Chaining – Saves the number of IP addresses or console/KVM ports that are required to manage all power distribution needs
- Integration with DSView 3 Management Software – Single interface for management of IT equipment and PDUs simplifies mapping of outlets to servers and other equipment in order to reduce and minimize power cycling the wrong equipment
- Integration with DSView 3 Software Power Manager Plug-In – Track historical trends to measure and monitor IT power consumption, capacity and cost in order to understand what issues exist and to make more informed decisions in the future
- Electronic Overcurrent Protection – An added layer of protection that is activated in the event of minor overloads; during such events, outlets are turned off first instead of the primary overcurrent protection (OCP) tripping
- Sequential Startup – Protects integrity of all upstream electrical infrastructure by staggering the inrush current draw of all plugged-in devices
- Internal Temperature Sensor and Two Optional External Sensors – These sensors can measure environmental factors at several different points within the rack
PM 1000
| Vertical and Horizontal
| Strip-level metering
| None
| Serial* or IP
| Single phase or three phase
| DSView 3 software or on-board Web interface
|
PM 2000
| Vertical and Horizontal
| Outlet-level metering
| None
| Serial* or IP
| Single phase or three phase
| DSView 3 software or on-board Web interface
|
PM 3000
| Vertical and Horizontal
| Outlet-level metering
| Outlet-level switching
| Serial* or IP
| Single phase or three phase
| DSView 3 software or on-board Web interface
|
PM 10
| Horizontal
| Strip-level metering
| Outlet-level switching
| Serial*
| Single phase
| DSView 3 software or on-board Web interface
|
PM 20
| Vertical
| Strip-level metering
| Outlet-level switching
| Serial*
| Single phase
| DSView 3 software or on-board Web interface
|
Direct_PDU
| Vertical and horizontal
| Strip-level metering
| Outlet-level switching
| IP
| Single phase
| On-board Web interface only
|
*Note - The serial interface option allows the PDU to connect to a supported Avocent appliance and share the IP connection of the main appliance.
Product Photos
Horizontal 6 Outlets

Vertical 24 Outlet - End

Vertical 24 Outlet - Middle

Vertical 24 Outlet

Related Photos
North America Models
PM 1000 Vertical Models with Strip-Level Metering
| PM 1000 0U Vertical 1-ph 208V 30A with L6-30, 21 C13 and 3 C19 outlets | PM1001V-401 |
| PM 1000 0U Vertical 3-ph 208V 30A with L21-30, 21 C13 and 3 C19 outlets | PM1002V-401 |
| PM 1000 0U Vertical 3-ph 208V 50A with Hubbell CS8365C, 21 C13 and 3 C19 outlets | PM1003V-401 |
| PM 1000 0U Vertical 3-ph 208V 60A with IEC309 60A, 21 C13 and 3 C19 outlets | PM1004V-401 |
| PM 1000 0U Vertical 3-ph 208V 30A with L15-30, 21 C13 and 3 C19 outlets | PM1008V-401 |
| PM 1000 0U Vertical 1-ph 30A 200 - 240V with L6-30, 20 C13 ports | PM1012V-401 |
| PM 1000 0U Vertical 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports | PM1014V-xxx* |
| PM 1000 1U Horizontal 1-ph 30A 200 - 240V with L6-30, 10 C13 ports | PM1009H-401 |
| PM 1000 1U Horizontal 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports | PM1011H-xxx* |
| *Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord) |
PM 2000 Models with Outlet-Level Metering
| PM 2000 1U Horizontal 1-ph 30A 208V, fixed cord with L6-30, 3 C19 ports | PM2001H-401 |
| PM 2000 1U Horizontal 3-ph 30A 208V, fixed cord with L15-30, 6 C19 ports | PM2002H-401 |
| PM 2000 1U Horizontal 3-ph 50A 208V, with Hubbell CS8365C, 6 C19 ports | PM2005H-403 |
| PM 2000 1U Horizontal 3-ph 60A 208V, with IEC 309 60A, 6 C19 ports | PM2005H-404 |
| PM 2000 1U Horizontal 3-ph 30A 208V, fixed cord with L21-30, 6 C19 ports | PM2006H-401 |
| PM 2000 0U Vertical 1-ph 30A 208V with L6-30, 21 C13 & 3 C19 ports | PM2001V-401 |
| PM 2000 0U Vertical 3-ph 30A 208V with L15-30, 21 C13 & 3 C19 ports | PM2002V-401 |
| PM 2000 0U Vertical 3-ph 30A 208V with L21-30, 21 C13 & 3 C19 ports | PM2006V-401 |
| PM 2000 0U Vertical 3-ph 50A 208V with Hubbell CS8365C, 21 C13 & 3 C19 ports | PM2005V-403 |
| PM 2000 0U Vertical 3-ph 60A 208V with IEC 309 60A, 21 C13 & 3 C19 ports | PM2005V-404 |
| PM 2000 1U Horizontal 1-ph 30A 200 - 240V with L6-30, 10 C13 ports | PM2007H-401 |
| PM 2000 1U Horizontal 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports | PM2009H-xxx* |
| PM 2000 0U Vertical 1-ph 30A 200 - 240V with L6-30, 20 C13 ports | PM2010V-401 |
| PM 2000 0U Vertical 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports | PM2012V-xxx* |
| *Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord) |
PM 3000 Models with Outlet-Level Metering and Outlet-Level Switching
| PM 3000 1U Horizontal 1-ph 30A 208V, fixed cord with L6-30, 3 C19 ports | PM3001H-401 |
| PM 3000 1U Horizontal 3-ph 30A 208V, fixed cord with L15-30, 6 C19 ports | PM3002H-401 |
| PM 3000 1U Horizontal 3-ph 50A 208V, with Hubbell CS8365C, 6 C19 ports | PM3005H-403 |
| PM 3000 1U Horizontal 3-ph 60A 208V, with IEC 309 60A, 6 C19 ports | PM3005H-404 |
| PM 3000 1U Horizontal 3-ph 30A 208V, fixed cord with L21-30, 6 C19 ports | PM3006H-401 |
| PM 3000 0U Vertical 1-ph 30A 208V with L6-30, 21 C13 & 3 C19 ports | PM3001V-401 |
| PM 3000 0U Vertical 3-ph 30A 208V with L15-30, 21 C13 & 3 C19 ports | PM3002V-401 |
| PM 3000 0U Vertical 3-ph 30A 208V with L21-30, 21 C13 & 3 C19 ports | PM3006V-401 |
| PM 3000 0U Vertical 3-ph 50A 208V with Hubbell CS8365C, 21 C13 & 3 C19 ports | PM3005V-403 |
| PM 3000 0U Vertical 3-ph 60A 208V with IEC 309 60A, 21 C13 & 3 C19 ports | PM3005V-404 |
| PM 3000 1U Horizontal 1-ph 30A 200 - 240V with L6-30, 10 C13 ports | PM3007H-401 |
| PM 3000 1U Horizontal 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports | PM3009H-xxx* |
| PM 3000 0U Vertical 1-ph 30A 200 - 240V with L6-30, 20 C13 ports | PM3010V-401 |
| PM 3000 0U Vertical 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports | PM3012V-xxx* |
| *Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord) |
Cables
| Set of 8 outlet cables: IEC320-C13 female to IEC320-C14 male | |
| Set of 10 outlet cables: IEC320-C13 female to IEC320-C14 male | ACS0046 |
Accessories
| Temperature and humidity combo sensor | PMHD-THS |
| Temperature only sensor | PMHD-TS |
Service Options
| 1 year Advanced Replacement | SCNT-PLUS-PM |
| 1 year 24/7 Technical Support and Advanced Replacement | SCNT-PREM-PM |
International Models
PM 1000 Vertical Models with Strip-Level Metering
| PM 1000 0U Vertical 1-ph 220/230/240V, 32A with IEC 309 32A, 21 C13 & 3 C19 | PM1005V-401 |
| PM 1000 0U Vertical 3-ph 380/400/415V, 16A with IEC 309 16A, 21 C13 and 3 C19 | PM1006V-401 |
| PM 1000 0U Vertical 3-ph 380/400/415V, 32A with IEC 309 32A, 21 C13 and 3 C19 | PM1007V-401 |
| PM 1000 0U Vertical 1-ph 32A 220/230/240V with IEC 309, 20 C13 ports | PM1013V-401 |
| PM 1000 0U Vertical 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports | PM1014V-xxx* |
| PM 1000 1U Horizontal 1-ph 32A 220/230/240V with IEC 309, 10 C13 ports | PM1010H-401 |
| PM 1000 1U Horizontal 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports | PM1011H-xxx* |
*Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord) |
PM 2000 Models with Outlet-Level Metering
| PM 2000 1U Horizontal 3-ph 16A 380/400/415V, fixed cord with IEC 309 16A, 6 C19 ports | PM2004H-401 |
| PM 2000 1U Horizontal 3-ph 32A 380/400/415V with IEC 309 32A, 6 C19 ports | PM2005H-406 |
| PM 2000 0U Vertical 1-ph 32A 220/230/240V with IEC 309 32A, 21 C13 & 3 C19 ports | PM2003V-401 |
| PM 2000 0U Vertical 3-ph 16A 380/400/415v with IEC 309 16A, 21 C13 & 3 C19 ports | PM2004V-401 |
| PM 2000 0U Vertical 3-ph 32A 380/400/415V with IEC 309 32A, 21 C13 & 3 C19 ports | PM2005V-406 |
| PM 2000 1U Horizontal 1-ph 32A 220/230/240V with IEC 309, 10 C13 ports | PM2008H-401 |
| PM 2000 1U Horizontal 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports | PM2009H-xxx* |
| PM 2000 0U Vertical 1-ph 32A 220/230/240V with IEC 309, 20 C13 ports | PM2011V-401 |
| PM 2000 0U Vertical 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports | PM2012V-xxx* |
*Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord) |
PM 3000 Models with Outlet-Level Metering and Outlet-Level Switching
| PM 3000 1U Horizontal 1-ph 32A 220/230/240V, fixed cord with IEC 309 32A, 3 C19 ports | PM3003H-401 |
| PM 3000 1U Horizontal 3-ph 16A 380/400/415V, fixed cord with IEC 309 16A, 6 C19 ports | PM3004H-401 |
| PM 3000 1U Horizontal 3-ph 32A 380/400/415V with IEC 309 32A, 6 C19 ports | PM3005H-406 |
| PM 3000 0U Vertical 1-ph 32A 220/230/240V with IEC 309 32A, 21 C13 & 3 C19 ports | PM3003V-401 |
| PM 3000 0U Vertical 3-ph 16A 380/400/415v with IEC 309 16A, 21 C13 & 3 C19 port | PM3004V-401 |
| PM 3000 0U Vertical 3-ph 32A 380/400/415V with IEC 309 32A, 21 C13 & 3 C19 ports | PM3005V-406 |
| PM 3000 1U Horizontal 1-ph 32A 220/230/240V with IEC 309, 10 C13 ports | PM3008H-401 |
| PM 3000 1U Horizontal 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports | PM3009H-xxx* |
| PM 3000 0U Vertical 1-ph 32A 220/230/240V with IEC 309, 20 C13 ports | PM3011V-401 |
| PM 3000 0U Vertical 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports | PM3012V-xxx* |
*Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord) |
Cables
| Set of 8 outlet cables: IEC320-C13 female to IEC320-C14 male | ACS0040 |
| Set of 10 outlet cables: IEC320-C13 female to IEC320-C14 male | ACS0046 |
Accessories
| Temperature and humidity combo sensor | PMHD-THS |
| Temperature only sensor | PMHD-TS |
Service Options
| 1 year Advanced Replacement | SCNT-PLUS-PM |
| 1 year 24/7 Technical Support and Advanced Replacement | SCNT-PREM-PM |
Mechanical
| 3 and 6 outlet models:
17 x 8.272 x 1.719 in.
(43.2 x 21 x 4.4 cm)
10 outlet models:
17 x 5.5 x 1.7 in.
(43.2 x 14 x 4.3 cm)
Power input cable length- 10 ft.
| 24 outlet models:
2.2 x 3.15 x 66 in.
(5.6 x 8 x 167.6 cm)
20 outlet models:
2.2 x 3.2 x 52 in.
(5.6 x 8.1 x 132.1 cm)
Power input cable length- 10 ft.
|
Weight
| 3 and 6 outlet models:
7.3 lbs. (without power cord)
10 outlet models:
5.2 lbs. (without power cord)
| 24 outlet models:
14.8 lbs.(without power cord)
20 outlet models:
11 lbs. (without power cord)
|
Network Connections
| 1- 10/100/1000 Ethernet
| 1- 10/100/1000 Ethernet
|
Serial Connections
| 2- (in/out for chaining purposes)
2 for external environmental sensors
| 2- (in/out for chaining purposes)
2 for external environmental sensors
|
Agency Approval
| UL, FCC, cUL, CE, VCCI, C-Tick, CB
| UL, FCC, cUL, CE, VCCI, C-Tick, CB
|
Note: The 20 outlet PM 1000 PDU height is 46 in.(116.8 cm)